CADPIPE Commercial Pipe 2002 6.6 Update

The following items are included in this upgrade:

  1. AutoCAD 2002 and Architectural Desktop 3.3 compatible.
  2. The ability to toggle between Commercial Pipe and HVAC without exiting AutoCAD.
  3. New directory structure allows greater flexibility.
  4. Database and Specification files can now be placed on a network and shared by multiple users.
  5. Users can now setup job specific database and specification files without copying and pasting multiple files to multiple workstations.
  6. Pipe size databases have been opened up to allow users to specify any pipe size.
  7. Metric pipe sizes can now use standard metric nominal sizes instead of conversion of imperial nominal sizes.
  8. Pipe lengths for waste pipe are now user defined (Pipe Length Override).
  9. Hub dimensions on DWV - With Hub are now user definable.
  10. The flange database has been opened up to allow users to define all dimensions of flanges.
  11. The olet database has been opened up to allow users to define the size range, dimension, type, and class of olets.
  12. New interface to NavisWorks. Enables CADPIPE intelligence to be carried into NavisWorks when viewing a CADPIPE model.
  13. Beams, columns, and walls can now be placed as AutoCAD solids.
  14. Pipe and Label reports now save with a .txt extension instead of an .rpt Makes finding and importing reports much easier.
  15. The ability to "Browse" for a location to backup and restore specs, databases, etc.
  16. Improved functionality for selecting which routing line to place a fitting on when more than one is in the selection set.
  17. The ability to edit the system and category on an existing routing line (This will not update any existing fittings on the routing line).
  18. When using a "Flanged" system, the flanges no longer report separately, but are included in the length of the pipe.
  19. Both flanges in a "Flanged" system are now erased when the pipe is erased.
  20. Walls, beams, and columns are now placed as AutoCAD solids. This will enable users to cut holes in these objects (sleeves, doors, windows, etc.) and use other solid editing tools.
  21. Architectural Desktop objects are now detected when pipe collides with them.

The following issues from Commercial Pipe 5.502 have been resolved:

  1. Solid adapters are now being placed on the correct spec layer.
  2. The size text now remains when converting pipe (mesh-solid-single line).
  3. The node on a flanged reducing tee is now placed at the correct location.
  4. Stretch now works with solid pipe.
  5. Corrected issue with single line Iso (Iso Pipe command) where the cut length reported was incorrect. This only occurred immediately after a 45 deg. elbow.
  6. Corrected issue with 3" X 1 ½" Sanitary Tee not modeling correctly.
  7. Resolved issue of screen flashing when a piece of pipe is placed while "Collision Check" is turned on.
  8. Resolved issue with Combo Wye & 1/8th Bend drawing pipe in the wrong direction.
  9. Using the "CADPIPE Copy" to copy fittings using an osnap as a basepoint and second point now functions correctly.
  10. Corrected modeling issue with Auto-routing using a "Sanitary Tee" as the turning fitting.
  11. Corrected issue with label function. Sometimes the origin of the leader on the label would originate at a the wrong location.
  12. Using "gaskets" with a "Flanged" system now reports the correct lengths.
  13. Corrected issues with sloped systems and "Fitting Conversion". No longer changes elbow and branch orientation when converted from mesh to solid, etc.
  14. Corrected issue with the CADPIPE Copy command causing an "Unhandled Exception" to occur when a piece of pipe was copied containing associated text placed by the "Query" command.
  15. Corrected issue with node placement on "Tees" that are placed "by center".
  16. Resolved issue with Victaulic cut lengths where the gaps were being subtracted from pipe length that was input via the keyboard.